Register address recorded in the schema description.
Multiplier applied during decode and inverted during encode.
Register description metadata.
Optionalopts: { readOnly?: boolean }
Optional domain schema and read-only setting.
An entry whose decoded values pass through the selected domain schema.
Scaled parameter where wire = domain / factor.
Decode validates through the optional domain schema so out-of-range values
fail. Set readOnly to make encode fail with readOnlyEncodeFailure
(monitor registers).
Encoding rounds value / factor. Supply a finite, non-zero factor.
An entry whose decoded values pass through the selected domain schema.
Scaled parameter where wire = domain / factor.
Decode validates through the optional
domainschema so out-of-range values fail. SetreadOnlyto make encode fail with readOnlyEncodeFailure (monitor registers). Encoding roundsvalue / factor. Supply a finite, non-zero factor.